Hybrid Controller – Shimaden SRP30 Series

Features

  • Adopts a large LCD for SRP33 (display area: 77 (W) × 57 mm (H))
  • Improved visibility and expressibility with a large 5-digit and 11-segment display
  • Achieves high precision of 0.1%FS and high resolution of 0.0001
  • The fastest sampling cycle is 50 ms (selectable from 50, 100, 200, and 500 ms).
  • Multi SV value setting: SV value can be set up to 9 points.
  • Multi PID: PID No. 1–9 (9 types)
  • Program function: up to 9 patterns and 180 steps
  • Dust and splash proof front panel equivalent to IP55
Enquiry

SRP30 Series works as both a high-performance controller and a high-performance program controller. Exclusive setup software enables an initial setting on the PC and the set data can be easily transferred to the instrument using the front panel USB port (communication is possible without the controller power source).

Ordering Information

ITEM CODE SPECIFICATIONS
.

.SERIES

SRP33- 96 x 96 DIN size Hybrid controller……………………………… TC, RTD, mV, V, mA Full multi input (mA is input by externally attached resistor) DI2 points, EV3 points, USB Communication SRP34- 48 x 96 DIN size standard equipment
SRP34- 48 x 96 DIN size Hybrid controller
v

d

CONTROL OUTPUT 1

Y Contact: 1a contact capacity 240 V AC 2.5 A/resistive load, 1 A/inductive load
I Current: 4–20 mA DC, Load resistance: 600Ω or below
P SSR drive voltage: 12 V ± 1.5 V DC, Load current: 20 mA or below
V Voltage: 0–10 V DC, Load current: 2 mA or below
.

.

.

CONTROL OUTPUT 2
(OPTION)

N- Without
Y- Contact: 1a contact capacity 240 V AC 2.5 A/resistive load, 1 A/inductive load
I- Current: 4–20 mA DC, Load resistance: 600Ω or below
P- SSR drive voltage: 12 V ± 1.5 V DC, Load current: 20 mA or below
V- Voltage: 0–10 V DC, Load current: 2 mA or below
E- EV4 Contact, 1a contact capacity, 240 V AC 2.5 A/resistive load, 1 A/inductive load
.

EXTERNAL CONTROL INPUT (DI) (OPTION)

0 Without
1 5 points (DI3–7) *3
.

.

ANALOG OUTPUT (AO)
(OPTION)

0 Without
3 Voltage: 0–10 mV DC, Output resistance: 10Ω
4 Current: 4–20 mA DC, Load resistance: 300Ω or below
6 Voltage: 0–10 V DC, Load current: 2 mA or below
.

EXTERNAL CONTROL OUTPUT (DO) (OPTION)

0 Without
1 3 points (DO1–3)
Darlington open collector output: 24 V DC 50 Ma
.

.

.

ADDITIONAL DO/CT/REM (OPTION)

0 Without
1 Additional DO3 points (DO4–6)
Darlington open collector output: 24 V DC 50 mA *1
2 CT input 2 points, amperage display 0.0–55.0 A *2
4 Remote setting input 4–20 mA DC/receiving impedance 250Ω (Uninsulated)
5 Remote setting input 1–5 V DC/input resistance approximately 500kΩ (Uninsulated)
6 Remote setting input 0–10 V DC/input resistance approximately 500kΩ (Uninsulated)
.

.COMMUNICATION (OPTION)

0 Without
5 RS-485 Shimaden standard protocol/MODBUS communication protocol
7 RS-232C
.

REMARKS

0 Without
9 With

 

Download